Jog Forward has the fifth highest operating priority. Use Jog Forward to “Jog” the drive Forward at the rate
indicated in Jog SP (CP-240). The acceleration and deceleration ramps are dictated by Acl Tm Jog (CP-241),
Dcl Tm Jog (CP-243) and Jog SP (CP-240). After the Jog Forward input is deactivated and the ramped
reference has reached “0”, the CX-1200 automatically reverts to the R-Stop operating state.

To activate Jog Forward:

Activate Low (closed to common), Level Sensitive, Not-Latched
Use momentary contact - needs to be maintained to remain active

Jog Forward

Common

F-Stop

R-Stop

H-Stop

Run

Common

Jog Fwd

Run

Close Maintained

6

8

1

2

4

5

3

J6

H-Stop

R-Stop

F-Stop

Figure 2-50 Jog Forward Input