Run has the fourth highest operating priority. Run is the primary operating state. RUN Mode (CP-202)
determines the mode of operation for Run, using either the master mode, the follower mode, the direct mode.
The corresponding setpoint for the selected mode determines the operating speed. RUN Mode (CP-202)
determines the control loop that is used during Run. At times, the selected RUN Mode is overridden. The
direct mode will only operate in an open loop. The master mode will “Run” in velocity loop. Therefore, the
follower mode is the only mode that can “Run” with the “velocity loop” or the “Position loop”.

With the exception of the direct mode, the acceleration and deceleration ramps for the modes of operation
are determined by Acl Tm RUN, (CP-301), Dcl Tm RUN (CP-303) and Ref Ramps (CP-300). The direct
mode ramps are determined by Acl Tm Drct (CP-231), Dcl Tm Drct (CP-232) and Ref Ramps (CP-300).

To activate Run:

Activate Low (closed to common), Level Sensitive, Latched
Use momentary contact - does not need to be maintained to remain active

Run

Common

F-Stop

R-Stop

H-Stop

Common

Run

Close Momentarily

5

8

1

2

4

3

J6

H-Stop

F-Stop

R-Stop

Figure 2-49 Run Input