CONTREX CX-1200 User Manual

Page 42

Advertising
background image

Page 40

Figure 2-42 Analog Input 1: Potentiometer Input

1

2

3

4

JA

+12V_Aux*

Common

+

-

Figure 2-43 Analog Input 2: Potentiometer Input

1

2

3

4

JA

+12V_Aux*

Common

+

-

Analog Input 1:

Potentiometer Input Wiring
(JA, Pins 1, 2, 4, 8)

The Analog Input 1 can be used with a potentiometer
(e.g., dancer pot). Figure 2-42 displays this option.

*

The total current from JA pin 1 and J5 pin 1
(+12V_Aux) must not exceed 150 mA.

Analog Input 2:

Potentiometer Input Wiring
(JA, Pins 1, 5, 7, 8)

The Analog Input 1 can be used with a potentiometer
(e.g., dancer pot). Figure 2-43 displays this option.

*

The total current from JA pin 1 and J5 pin 1
(+12V_Aux) must not exceed 150 mA