C - 14

CP-70

DEVICE ADDRESS

Device Address (CP-70) is the physical address of the MLP–Trim, which can be set from 1 to 32.
Each individual MLP–Trim on a multidrop RS485 communications link needs a unique Device
Address. The address “00” will be globally accepted by all of the MLP–Trims on a
communications link, however, they will not send a response message back to the host computer
when this global address is used.

CP-71

BAUD RATE

There are six different baud rates (data rates) for the MLP–Trim. Enter the number for the
required function in Baud Rate (CP-71), as listed below.

1 = 300 Baud
2 = 600 Baud
3 = 1200 Baud
4 = 2400 Baud
5 = 4800 Baud
6 = 9600 Baud

CP-72

CHARACTER FORMAT

The MLP–Trim uses three different character formats. Enter the number for the required format
in Character Format (CP-72), as listed below.

1 = 8 Data Bits, No Parity, One Stop Bit
2 = 7 Data Bits, Even Parity, One Stop Bit
3 = 8 Data Bits, No Parity, Two Stop Bit

CP-73

CONTROL MASK

The Serial Communications can control some of the logic input functions. Enter the number for
the required functions in Control Mask (CP-73), as listed below.

0 = F–Stop only
1 = F–Stop, Run, R–Stop
2 = F–Stop, Master/Follower, Setpoint Select
3 = All of the above