3 - 36

Table 3-26 Entering Follower Scaling Analog Setpoint Parameters

CP

Parameter Name

Parameter Value

CP-84

Analog Input Allocation

CP-21

Follower Engineering Units

CP-34

Max RPM Feedback

CP-31

PPR Feedback

CP-33

Max RPM Lead

CP-30

PPR Lead

Setting CP-84 to a value of "6" or "7"
allocates the analog input to be used
as the Follower Setpoint 1 or Follower
Setpoint 2, respectively.

Enter the Follower Engineering Unit
value for an analog setpoint level of
10.0 volts with a lead of Max RPM
Lead (CP-33) and feedback of Max
RPM Feedback (CP-34).

Enter the maximum operating RPMs
measured at the feedback sensor shaft.

Enter the resolution of the feedback
sensor.

Enter the maximum operating RPMs
measured at the lead sensor shaft.

Enter the resolution of the lead
sensor.