3 - 29

Table 3-20 Entering Follower Scaling Analog Lead Parameters

CP

Parameter Name

Parameter Value

CP-84

Analog Input Allocation

CP-21

Follower Engineering Units

CP-34

Max RPM Feedback

CP-31

PPR Feedback

Setting CP-84 to a value of "1"
allocates the analog input to be used
as the lead signal.

Enter the Follower Engineering Unit
value for an analog lead level of
10.0 volts and feedback of Max RPM
Feedback (CP-34). This is typically a
value of 1.000.

Enter the maximum operating RPMs
measured at the feedback sensor shaft.

Enter the resolution of the follower
feedback sensor.

Note:

The Max RPM Lead (CP-33) and PPR Lead (CP-30) control parameters, used

for scaling Follower mode with a frequency lead, are ignored when using
analog lead scaling.