PLUNGER RETAINER
INJECTOR SEAL
Catalyst Injector Disassembly
1. Remove Injector Seal (5104-13-1) from Injector Body (5104-15-1)
2. Unscrew Plunger Retainer (5104-14-1) from Injector Plunger (5104-16-1)
3. Remove Compression Spring (9203-2-2) from Injector Plunger (5104-16-1)
4. Remove Injector Plunger (5104-16-1) from Injector Body (5104-15-1)
5. Reassemble with new parts as required.
NOTE: Discard all parts to be replaced by the repair kit. All remaining parts
should be thoroughly cleaned, inspected for damage, and replaced if necessary.