Assemble flush valve, Assembly gun head and gun handle – Magnum Venus Plastech DuraMAX Gun DMX-3000 User Manual

Page 24

Advertising
background image

DuraMAX Gun Manual

Rev. 12/2012

Page | 24

Assemble Flush Valve

1. Place the O-ring (O-K-008) on the flush valve button (5104-25-1).

2. Insert the spring (9203-2-3) onto the flush valve button.

3. Push the button and spring into the flush valve body (5104-24-1).

4. Place the O-ring (O-A-007) on the flush seal body (5104-23-1).

5. Insert a flush seal body (5104-23-1) into the end of the flush valve body and screw it

onto the button.

6. Place a flush valve seal (5104-26-1) on the flush valve body.

7. Install the flush valve body (5104-24-1) into the flush valve neck (5104-22-1).

8. Install the split seal (5104-21-1) onto the flush valve body (5104-24-1).

Note: If using O-ring part number O-K-008 (O-ring is used on the flush button),
you do not need to replace the O-ring unless it is showing obvious signs of wear
or damage. This O-ring is specially designed for use with all solvents.


WARNING: Be careful not to bend the catalyst and resin needles.

Assembly Gun Head and Gun Handle

1.

Attach the Gun Head Assembly (DMX-3001-01) to the Gun Handle (54350-3) using Cap
Screw (F-CS-04C-12).

2.

Slide Trigger (54360-1) into place against the needles and line up the holes with the
handle.

3.

Push Trigger Stud (54630-1) thru both the Trigger (MAX-2040) and the Gun Handle
(54350-3) and retain with Screw (00145).






Advertising