Resin Problems

1. Resin leaking around Needle (inside Needle Housing CPR-2004-01)

—

Check that the needle is not bent

—

Lightly tighten Packing Nut (MG-2022)

—

Replace Packing Seal (MAX-2008)

2. Resin leaking around Needle Housing

—

Replace O-Ring (O-S-012) on Needle Housing (MAX-2013)

3. Resin leaking from the Mix Housing / front of the gun

—

Check Piston Needle (MAX-2010-01) for wear or damage, replace as needed

—

Check Carbide Seat (MAX-2011-01) for wear or damage, replace as needed

—

Replace O-Ring (O-T-010) under the Carbide Seat (MAX-2011-01)

—

Damaged or Weak Return Spring (04039-1), replace as needed

—

Check for excessive pressure in resin system

4. No Resin from the gun

—

Make sure trigger is pulling resin needle back / open

—

Check gun block for blockages

—

Check resin pump for proper operation (See resin pump manual)

5. Resin leaking between fitting and gun block

—

Replace O-Ring (O-S-012) on fitting

6. Resin leaking from around the resin shut off needle

—

Lightly tighten Packing Nut (DMX-3002)

—

Replace O-Ring (O-T-010)

Flush Problems

1. Solvent leaking from around flush button (inside flush body)

—

Replace O-Ring (O-E-008)* on valve button

2. Solvent leaking from around flush neck (next to gun block)

—

Replace Split Seal (5104-21-1)

3. Solvent leaking from between the flush neck and flush body

—

Replace Flush Valve Seal (5104-26-1)

4. Solvent leaking around flush elbow fitting

—

Tighten flush swivel Elbow Fitting (TRU-1021)

—

Replace Nylon Seal (7304-3-1)

—

Replace flush swivel Elbow Fitting (TRU-1021)

5. Solvent leaking from Mix Housing / front of the gun

—

Check for debris in seal area or damage to flush body

—

Replace O-Ring (O-A-007) on flush seal body

—

Check for excessive pressure is flush system, set to no more than 80psi