General Problems

1. Material leaking from around the mix chamber

— Replace Mix Housing Seal (O-S-018)

— Replace Catalyst Injector Seal (5104-13-1)

2. Air leaking from around poppet needle

— Tighten Retainer (54420-1) (caution do not over tighten, this will make the poppet

needle move slowly or not move at all.)

— Replace O-Ring (O-S-104A)

3. Air leaking from around poppet valve body

— Tighten Poppet Valve Body (54440-1) into Gun Handle (54350-3)

4. Air leaking from fitting on handle or to chopper

— Retainer (54420-1) may be too tight and holding valve open

— Check Poppet Assembly (MG-2031) for wear or damage

— Check Poppet Valve Body (54440-1) seat area for ware or damage

5. Material leaking from around nozzle or nozzle cap

— Tighten Nozzle Cap (8704-4-1) (caution do not over tighten or you may damage

the Turbulent Mixer (5107-27-3) Hand tighten only

— Check Turbulent Mixer (5107-27-3) for damage or ware

— Check front of Mix Housing (MAX-2017-T) for damage

6. Trigger Action stiff or hard

— Check Trigger (54360-1) for damage

— Check Trigger Stud (54630-1) and Screw (00145) for damage, remove and
lubricate as needed.

— Check Needle Guides (53900-1) and Springs (04039-1) for damage, remove and
lubricate as needed

— Check Spring Retainer (54000-1) for ware or damage

— Check Needles and Needle Housings for hardened or sticky material