Troubleshooting – Magnum Venus Plastech DuraMAX Gun DMX-3000 User Manual

Page 26

Advertising
background image

DuraMAX Gun Manual

Rev. 12/2012

Page | 26

Troubleshooting:


Catalyst Problems

1.

Catalyst leaking around Needle (inside packing nut)

— Lightly tighten Packing Nut (MG-1022)

— Replace Packing Seal (MAX-2008)

— Check for excessive pressure in catalyst system

— Check that the needle is not bent

2.

Catalyst leaking around Needle Housing

— Replace O-Ring (O-S-012) on Needle Housing (CPR-2003-02)

3.

Catalyst leaking from the Mix Housing / front of the gun

— Check Catalyst Piston Needle (DMX-3008-01) for ware or damage

— Replace Catalyst Seat (CPR-2012-02)

— Replace O-Ring (O-S-012) under the catalyst seat

— Damaged or Weak Return Spring (04039-1), replace as needed

— Check for excessive pressure in catalyst system

— Check to see if the resin needle is bent

4.

Catalyst leaking from around plug on the side of the gun head

— Replace plug Seal (02441-1)

5.

No catalyst from the gun

— Make sure trigger is pulling catalyst needle back / open

— Check Catalyst Injector (5104-03-01) for proper operation (drawing 5104-03-01)

— Check gun block for blockages

— Check catalyst pump for proper operation (See catalyst pump manual)

6.

Catalyst leaking between fitting and gun block

— Replace O-Ring (O-S-012) on fitting

7.

Catalyst leaking from around the catalyst shoot off needle

— Lightly tighten Packing Nut (DMX-3002)

— Replace O-Ring (O-T-010)










Advertising