Micromod Micro-DCI: 53SL6000 Single Loop Controller User Manual

Page 134

Advertising
background image

K11: Characterizer constant 11.
K12: Characterizer constant 12.
K13: Characterizer constant 13.
K14: Characterizer constant 14.
K15: Characterizer constant 15.
K16: Characterizer constant 16.
K17: Characterizer constant 17.
K18: Characterizer constant 18.
K19: Characterizer constant 19.
K20: Characterizer constant 20.
K21: Characterizer constant 21.
K22: Characterizer constant 22.
K23: Characterizer constant 23.
K24: Characterizer constant 24.
K25: Characterizer constant 25.
K26: Characterizer constant 26.
KEY: Key module.
KP: Easy-Tune calculated gain.
K-SP: Ratio setpoint mode.
K.tc: Thermocouple type K.
-/L: Low alarm only.
LFLo: Linear flow compensation.
LG: Logic module.
LG1: Logic module 1 output.
LG1.A: Logic module 1 A input selector.
LG1.b: Logic module 1 b input selector.
LG1.M: Logic module 1 mode selector.
LG2: Logic module 2 output.
LG2.A: Logic module 2 A input selector.
LG2.b: Logic module 2 b input selector.
LG2.M: Logic module 2 mode selector.
LG3: Logic module 3 output.
LG3.A: Logic module 3 A input selector.
LG3.b: Logic module 3 b input selector.
LG3.M: Logic module 3 mode selector.
LG4: Logic module 4 output.
LG4.A: Logic module 4 A input selector.
LG4.b: Logic module 4 b input selector.
LG4.M: Logic module 4 mode selector.
L/LL: Low/low-low alarm indicators.
LiM: Limiter function.
L.LiM: Low limiter control scheme.
Lin: Linear.
LoG: Logarithmic function.
LSEG: Linear segment characterize.
L.tc: Thermocouple type L.
MFd: Manual feedback disable.
MMt: Minimum manual time.
Mr: Manual reset.
nc: No connect.
no: No.
nonE: None.
n.tc: Thermocouple type n.
oFF: Off.
oh: Output high limit.
oL: Output low limit.
oPEr: Operator menu.
oPr: Operator module.
oPtA: Option A.

oPtb: Option b.
or: A OR B logic function.
or/: A OR NOT B logic function.
/or: NOT (A OR B) logic function.
oSr: Output slew rate.
out: Control output.
oVtS: Output track status.
P: Proportional.
PD: Proportional and derivative.
PI: Proportional and integral.
PID: Proportional, integral, derivative.
PA1: cn.1 AL1 status.
PA2: cn.1 AL2 status.
PA1.2: cn.2 PL1 status.
PA2.2: cn.2 PL2 status.
Pb: Proportional band.
PGrM: Setpoint Programmer.
Pid.E: Enable oPEr tuning access.
PKEY: Program menu pass-key module.
PL1: Process alarm limit 1.
PL2: Process alarm limit 2.
PLiM: Enable parameter modify.
PL.tc: Thermocouple type PLII (platinel).
PoLY: Polynomial function.
PoWr: Exponential function.
P.DDD: Red/green dro decimal selection.
PP.DD: Red/green dro decimal selection.
PPP.D: Red/green dro decimal selection.
PPPP: Red/green dro no decimal.
PrG: Program module.
ProG: Program menu.
Pt.85: 100 ohm platinum RTD .00385

α

.

Pt.91: 100 ohm platinum RTD .00391

α

.

Pt.92: 100 ohm platinum RTD .00392

α

.

PV: Process variable.
PVt: Process variable tracking loop 1.
PVt.2: Process variable tracking loop 2.
rEV: Reverse.
rMt: Remote.
rSV: Reverse output indication.
rSW: Reverse control action.
r.tc: Thermocouple type r.
rtd: RTD 3 or 4 wire selection.
run: Run.
run?: Run query.
SchM: Control scheme selector.
SEL: Selector function.
SFLo: Square root flow compensator.
Sh: Setpoint high limit.
SL: Setpoint low limit.
SnGL: Single loop control scheme.
SP: Control setpoint.
SPAn: Span.
SPM: Setpoint mode.
SPtS: Setpoint track status.
SQrt: Square root signal.
SSr: Setpoint slew rate.
S.tc: Thermocouple type S.

Appendix D. Prompt List

53SL6000 Instruction Manual

D-3