Page 36

iPort

®

Integration (Continued)

IW-22

In the ATON configuration software determine which Comm Port and Source Audio Input
you will be using to connect to the iPort. Connect all iPort components according to the

IW-22 installation manual. Verify functionality of the IW-22.

Connect a Cat5 (TIA/EIA568A or B) from the selected Comm Port of the AH66T to the
DB9M-RJ45 adapter. Connect the RS-232 Control Cable (included with the IW-22) to the
adapter. If IR control is also required, connect the IR Emitter Output of the AH66T to the IR
input port of the IW-22’s Audio Wall Plate. Connect the audio output of the IW-22 Audio
Wall Plate to the Source Audio Input of the AH66T.

Figure 4-3: IW-22 Connections

iPort feedback is only displayed on the OLED2s. It does not “pass through” to 3

rd

party

controllers.