3rd Party RS-232 Control Integration

In the ATON configuration software configure Com 1 of the AH66T (chassis # 1 only) for 3

rd

party serial control.

Connect a Cat5 (TIA/EIA568A or B) from Com 1 of the AH66T to the DB9F-RJ45 NULL
Modem
adapter. Connect a serial cable from the adaptor to the RS-232 port of the 3

rd

party control device

The MAXIMUM total wire run length from the AH66T’s Comm Port to the RS-232 port of

the 3

rd

party controller is 50’ (15m).

Figure 4-6: RS-232 Connection

You must download RS-232 configuration settings to the AH66t to enable it to work with
the 3

rd

party controller being used. This programming is done in the ATON configuration

software. Connect a USB to USB-Mini from the computer to the AH66T to download these
settings.

See Appendix A for the Serial Protocol and command set.