14

Panel switch to the “OFF” position. When the Control Panel Switch is once again set to the “ON” position, the
MVP will announce “Voice Annunciator enabled.” This will be followed by the announcement of any active alarms.

Adjusting the Volume of the Voice Warnings: The “Voice & Display Controls” screen provides a control to
adjust the volume level of the voice warnings. To navigate to the “Voice & Display Controls” screen start by
viewing the Main Engine Screen, push the Menu button and select the “Voice & Display Controls” screen near the
bottom of the page.

False Alarms: As with any warning system, it is important there are no false alarms. False alarms can desensitize a
pilot to all alarms, which can cause a serious situation to go undetected. Setting proper red and yellow limits for
each function is a key step in eliminating false alarms.

2.9 Disabling a Display:

Any display shown on the Main Engine or System Screen may be disabled. This allows an improperly operating
function on the MVP to be designated “DISABLED.” To disable an MVP instrument display, see the “4. Redlines,
Limits and Color Setup” screen. This feature is password protected.