6. Navigate to the “4. Redlines, Limits and Color Setup” screen. Select the appropriate Gear for the Function.
For each of the Gear Lights connected to the EDC, set the Range Markings as follows:

For a High Reading when the Gear Light is on:

Set “White” From “0.0” To “3.0”
Set “Green” From “3.0” To “100.0”

For a Low Reading when the Gear Light is on:

Set “White” From “3.0” To “100.0”
Set “Green” From “0.0” To “3.0”