A3.0 Appendix:

Calibrating Airspeed

1. Connect the Calibrated Pressure Source to the pitot tube and static ports as required.

2. Navigate to the “5. EDC Input Calibration” screen:

Start with the “Main Engine Screen” and push the MENU button.
Select the “System Configuration Screens Menu” at the bottom of the screen.
Select the “5. EDC Input Calibration” screen.

3. Select the “Input” with the “AIRSPD” Function.

4. With the Calibrated Pressure Source set to 0 knots, adjust the MVP “Offset” so the “Processed Value”

displays 0 kts.

5. With the Calibrated Pressure Source set to the top end airspeed for your aircraft, adjust the MVP “Gain”

so the “Processed Value” matches the Calibrated Pressure Source.