1. Never operate this appliance within 10 feet (3.05m) of any structure, combustible material or

other gas cylinder. Never operate this appliance within 25 feet (7.5m) of any flammable liquids or

vapors.

2. There must be no combustibles or roof overhead.

3. Keep 24” (.61m) of space between the LP gas cylinder and the appliance.

4. The LP gas cylinder and appliance must be located so that any wind is blowing the heat of the appliance away

from the propane cylinder. This also helps fire prevention by blowing the flames of a grease fire away from the

propane cylinder.

5. Center the pot over the burner on the cooker. Do NOT use any pot larger than the recommended size for your

cooker as listed below:

cooker Height maximum Pot size Pot - Height/diameter

12” (30.5 cm) 32 qt. pot 12” x 14” (30.5 cm X 35.5 cm)

14.5” (37 cm) and Taller 30 qt. pot 16”x12 3/8” (40.6 cm X 31.5 cm)

21

PlAcement InstructIons

connectIon InstructIons

1. Check that your hose assembly is set to not allow gas flow. Turn the regulator control counterclockwise

until it stops. This is the OFF position.

2. Attach the regulator to the cylinder valve by turning the Type 1 fitting clockwise. Hand tighten with the

regulator positioned upright. Refer to the appropriate assembly diagram for the appliance, page 12,

Figure 1 or 2.

3. Perform the Leak Test:

4

. Before lighting the cooker, check that the venturi tube is free of obstruction and that the orifice is properly

threaded into the venturi tube as per the hose connection instructions on pg. 12. Both situations must be

corrected if necessary before lighting to prevent flashback.

leAK test

Before lighting the appliance, a thorough leak test must be satisfactorily completed using

a non-ammonia soapy water solution (50% non-ammonia soap and 50% water). This is to be

applied with a small brush to all gas joints after the cylinder valve is opened (no more than

1/2 turn). If bubbles are seen, indicating a leak, turn off the cylinder and tighten the leaking

connection until a further leak test shows no leaks.

If tightening the connection does not stop the leak, call Metal Fusion, Inc. (800) 783-3885,

for assistance.

neVer use Hose/reGulAtor Assembly IF leAKInG.

FIGure 1

(3.05m)

(.61m)

(3.05m)