Data Communications

23

Xon/Xoff Flow Control

Host systems that use a simple three-wire RS232 connection (TXD, RXD,
GND) accomplish flow control by using Xon/Xoff or Robust Xon/Xoff. The
printer supports these modes and may be selected from the Operator Panel.

When using a three-wire RS232 connection, the printer must still detect the
DSR signal as ON. This requirement is addressed by adding a jumper between
RTS (pin 5) and DSR (pin 20) on the DB25 male connector on the printer
(Figure 9).

Figure 9 – Three-Wire Printer to DTE Host Cable Diagram

RXD 2

TXD 3
RTS 5

GND 7

DSR 20

2 TXD
3 RXD

7 GND

DTE Host

DB25 Connector

4500 Series Printer

DB25 Connector