Print Darkness Control

CodeWriter 4500 Series Printers shipped with this manual

4

will contain a new Print

Darkness control method. This method replaces the print settings method that
involved a Contrast and Preheat setting. The Operator Panel includes access to these
former methods to service current customers obtaining satisfactory print quality with
those settings. Customers desiring to use this previous method may use the following
procedure.

New Customers not obtaining satisfactory results with the Print Darkness method
should contact their Datasouth representative for additional assistance.

Setting Contrast and Preheat

Use the following procedure the program the printer’s Contrast and Preheat
parameter values:

1. Press the

ONLINE

PAUSE

key. This takes you to the off-line menu.

2. When Interface Status Off-Line is displayed, press the

MENU

key. This

will take you the to the Print Parameters menu.

3. Press the

ITEM

FEED

key until ENTER to Select Expert Settings is displayed.

4. Press the

ENTER

PRINT

key.

5. Print Cont. is the first parameter displayed. Press the

or

CANCEL

key

to change the Contrast value.

NOTE: When changing values using the

or

CANCEL

keys, a

single key press will change the value by one unit. If the key is
pressed and held in, the value will change by 10 units.

6. Press the

ITEM

FEED

key. Pre-Heat is the next parameter displayed. Press the

or

CANCEL

key to change the Preheat value.

7. Press the

ONLINE

PAUSE

key, followed by the

ONLINE

PAUSE

key. The display will read

ENTER to save new defaults. Press the

ENTER

PRINT

key to save these values.

Or Press the

MENU

key to return to the Print Parameters menu.