Troubleshooting Guide

50

The ribbon sensor indicates a thermal transfer ribbon is present while in direct
thermal mode. If direct thermal mode is desired and the ribbon is removed,
then one of the following conditions has occurred. (This procedure only
applies to Thermal Transfer printers operating in Direct Thermal mode.
Should this message occur on a Direct Thermal printer, contact qualified
service personnel.)
1. The sensor’s sensitivity is incorrectly adjusted. See Adjusting Sensor

Sensitivity in this section.

2. The ribbon sensor system requires repair or replacement. Contact qualified

service personnel.

If thermal transfer mode is desired, press the

CANCEL

key and see this manual’s

Media Settings section to correctly set the Printing Mode.

The ribbon sensor does not detect a thermal transfer ribbon while in thermal
transfer mode. If the ribbon is properly installed and thermal transfer mode is
desired, then one of the following conditions has occurred.
1. The sensor’s sensitivity is incorrectly adjusted. See Adjusting Sensor

Sensitivity in this section.

2. The ribbon sensor system requires repair or replacement. Contact qualified

service personnel.

If direct thermal mode is desired, press the

CANCEL

key and see this manual’s

Media Settings section to correctly set the Printing Mode.

Remove Ribbon

PRINT or CANCEL?

Ribbon Out

PRINT or CANCEL?