Verifying the sensor operation, Troubleshooting guide – AMT Datasouth Codewriter 4500 Series User Manual

Page 73

Advertising
background image

Troubleshooting Guide

63

Verifying the Sensor Operation

The Operator Panel off-line menu provides a diagnostic tool to verify the operation
Gap Sensor operation.

1. Press the

ONLINE

PAUSE

key. This takes you to the off-line menu.

2. When Interface Status Off-Line is displayed, press the

MENU

key until

System Params. is displayed.

3. Press the

ITEM

FEED

key until the ENTER to Select Diagnostics is displayed.

4. Pressing the

ENTER

PRINT

key will cause the display to read as follows:

Correctly configured sensor sensitivity levels will display the following
information:
ƒ

Gap Sensor Mode for Media Sensor (material in guide block sensor)

Gap (or Backing): Med = 001
Label Stock: Med = 000

ƒ

Black Bar Mode for Media Sensor (material in guide block sensor)

Black Bar: Med = 000
Label Stock: Med = 001

ƒ

Ribbon Sensor

Ribbon Present: Rib = 000
Ribbon Out or Trailer: Rib = 001

5. Return to Online status by pressing the

ENTER

PRINT

key, followed by the

ONLINE

PAUSE

key.

Med Rib
00X 00X

Advertising