NOTE: Both summer and winter programs use the same time settings and programmable fan settings.

Setting

Time

Summer

Winter

MORN

6:00 a.m.

76

70

DAY

8:00 a.m.

82

60

EVE

5:00 p.m.

75

68

NIGHT

11:00 p.m.

78

66

Setting

Time

Summer

Winter

MORN

DAY

EVE

NIGHT

Sample Program

Your Program

NOTE: If "AUTO CHANGEOVER" was enabled during installation, refer to "SELECTING AUTO CHANGEOVER" for
restrictions on setting heating or cooling setpoint temperatures for proper operation. AUTO (changeover) will not
function unless the thermostat is set to PROGRAM mode. If "AUTO CHANGEOVER" was disabled during installation,
you may set heating or cooling setpoints to any temperature settings you desire.

PROGRAMMING

24

You may press the

∨ or ∧ buttons to temporarily change the

programmed temperature while in COOL or HEAT mode. The

∨ or

∧ buttons will not change the setting while the system is in
AUTO. You may also press the PROG/MAN button to change to
manual mode and manually change the temperature settings.

Resetting the Thermostat

If you ever experience a problem with the thermostat and find it is
not working correctly, or want to erase the ENTIRE program,
simply press and release the reset button. To access the RESET
button, remove thermostat from wiring subbase. (See
“REMOVING THERMOSTAT FROM WIRING SUBBASE.”) Note
reset location as shown in Figure 2. Use a small pin or paper clip
to push in the reset button.

The reset button is only accessible when the main unit is removed
from the wiring subbase. See “REMOVING THERMOSTAT FROM
WIRING SUBBASE.” This button will clear all the programs you
have set and revert to the default settings.

RESET

-

+ -

+

-

+ -

+

Figure 2