Programming, Checking filter monitor, Resetting filter monitor – Robertshaw 9700 User Manual

Page 20: Programming filter monitor

Advertising
background image

17

2. Press SET button. The display will show the current day of the

week or the last programmed day. Press

∨ or ∧ to advance to

the day of the week you will program.

3. Press SET button. The display will show the time setting:

4. Press either

∨ or ∧ button to adjust the time setting for MORN.

(Note: Either

∨ or ∧ button scrolls the time in 30 minute

increments.)

5. Press SET button. The display will show the setpoint

temperature.

6. Press either

∨ or ∧ button to adjust the temperature setpoint

for the programmed MORN time.

MON

MORN

AM

F

MON

MORN

MON

PROGRAMMING

SET

SET

SET

1. Press SET and FILTER buttons at the same time. Release both

buttons. The display will show:

2. Press

∨ or ∧ button to change filter hours setting (0 to 960). The

default is 240 hours (based on average 30 day month at 8 hours
per day fan operation). A setting of 0 disables this function.

3. Press SET button to save setting.

Checking Filter Monitor

1. Press FILTER button. The current hours of fan operation since

last reset are shown for reference.

2. The main display will return after a few seconds.

Resetting Filter Monitor

1. When filter needs to be serviced, "Check Filter" will show in main

display indicating that the hours of fan operation have met your
programmed filter servicing interval.

2. After servicing the filter, repeat steps 1-3 to reset/reprogram your

filter monitor.

20


CHECK
FILTER

PROGRAMMING

Programming Filter Monitor

The filter monitor keeps track of the total time the system fan has been in operation during the heating or cooling modes.
The "Check Filter" message appears when the hours of fan operation equals your programmed filter monitor hours setting.

SET

FILTER

SET

FILTER

Advertising