13. Maintenance and Inspection

[How to apply grease for guide rail]

Short types Ball Guide Type (Option: Model Code BG)

1) To apply grease, supply it from the grease injection gate (

φ1.2) shown in the figure below with using

an injector.
The following table shows the volumes of grease application for each model as a reference.
There is a tendency that the resistance in sliding operation increases after grease is supplied.
Remove excessive grease and then run the actuator back and forth for 10 to 20 times for a break-in.

Grease Apply Volume (1 block)

Ball Running Surface

Grease Injection Gate (

φ1.2)

The guide constructed in the Ball Guide Type is equipped with a built-in lubrication
system, however, in a short distance travel, the lubricant may not get spread out evenly.
Check the lubricant condition regularly, and supply grease if necessary.

Caution:

In case the grease got into your eye, immediately go to see the doctor to get an
appropriate care.
After finishing the grease supply work, wash your hands carefully with water and soap
to rinse the grease off.

Caution: