IAI America PCON-CFA User Manual

Page 201

Advertising
background image

4. SCON-CA


195


(* In the table, ON indicates that the applicable bit is “1,” while OFF indicates that the bit is “0.”)

Signal type

Bits

Symbol

Description

Details

Current

position

32-bit data

-

32-bit signed integer indicating the current position.
The setting unit is 0.01 mm.
(Example) Reading: 000003FF

H

= 1023 (decimal)

= 10.23 mm

* If current positions are read as hexadecimals, negative values

are indicated by 2’s complements.

4.9 (3)

Command

current

32-bit data

-

32-bit integer.
The electrical current presently specified by a command is
indicated.
The setting unit is mA.
(Example) Reading: 000003FF

H

= 1023 (decimal)

= 1023 mA

4.9 (3)

Current

speed

32-bit data

-

32-bit integer.
The current speed is indicated.
The setting unit is 0.01 mm/sec.
(Example) Reading: 000003FF

H

= 1023 (decimal)

= 10.23 mm/sec

4.9 (3)

Alarm

code

16-bit data

-

16-bit integer.
If an alarm occurred, a corresponding alarm code is output.
If no alarm is present, “0” is set.
For details on alarms, refer to the operation manual for the
controller.

4.9 (3)

Force

feedback

data

32-bit data

-

32-bit signed integer
The current measurement on the load cell is indicated.
The unit is 0.01 N.
* If readings are expressed in hexadecimals, a negative value is
indicated by a two’s complement.

4.9 (3)

Total

moving

count

32-bit data

-

32-bit integer.
The unit is times.

-

Total

moving

distance

32-bit data

-

32-bit integer.
The unit is m.

-

b15 -
b14 -
b13 -
b12 -
b11 -
b10

-

b



-

b8 -
b7 -
b6 -
b5 -
b4 -
b3 -
b2 -

Not available.

-

b1

Home return complete: This signal turns ON when home return
is completed.

4.7.11 (32)

PLC in

put

Status

signal 1

b0

Position complete signal: This signal turns ON when positioning
is completed.

4.7.11 (28)

Advertising