4. SCON-CA


211


(* In the table, ON indicates that the applicable bit is “1,” while OFF indicates that the bit is “0.”)

Signal type

Bits

Symbol

Description

Details

Push-motion

current-lim

iting

value

16-bit data

-

16-bit integer.
Specify the current-limiting value to be used during push-motion
operation.
The allowable specification range is 0 (0%) to 255 (100%).
The actual allowable specification range varies from one
actuator to another. (Refer to the catalog or operation manual for
each actuator.)
If a move command is issued by specifying a value exceeding
the maximum push-motion current, an alarm will occur.

4.9 (2)

b15 BKRL

Forced brake release: The brake is released when this signal
turns ON.

4.7.11 (18)

b14 RMOD

Operation mode: The AUTO mode is selected when this signal is
OFF, and the MANU mode is selected when the signal is ON.

4.7.11 (19)

b13 DIR

Push direction specification:
When this signal is OFF, push-motion operation is performed in
the direction of the position determined by subtracting the
positioning band from the target position.
When the signal is ON, push-motion operation is performed in
the direction of the position determined by adding the positioning
band to the target position.

4.7.11 (22)

b12 PUSH

Push-motion specification: Positioning operation is performed
when this signal is OFF, and push-motion operation is performed
when the signal is ON.

4.7.11 (21)

b11
b10

- Not

available.

-

b9 CLBR

Load cell calibration command: Calibration is performed when
this signal turns ON.

4.7.11 (32)

b8 JOG+

+Jog: The actuator moves in the direction opposite home when
this signal is ON.

4.7.11 (13)

b7 JOG-

-Jog: The actuator moves in the direction of home when this
signal is ON.

4.7.11 (13)

b6 JVEL

Jog-speed/inch-distance switching: The values set in parameter
No. 26, “Jog speed” and parameter No. 48, “Inch distance” are
used when this signal is OFF, and the values set in parameter
No. 47, “Jog speed 2” and parameter No. 49, “Inch distance 2”
are used when the signal is ON.

4.7.11 (14)

b5 JISL

Jog/inch switching: Jog operation is performed when this signal
is OFF, and inch operation is performed when the signal is ON.

4.7.11 (15)

b4 SON

Servo ON command: The servo turns ON when this signal turns
ON.

4.7.11 (5)

b3

RES

Reset: A reset is performed when this signal turns ON.

4.7.11 (4)

b2

STP

Pause: A pause command is issued when this signal turns ON.

4.7.11 (11)

b1 HOME

Home return: A home-return command is issued when this signal
turns ON.

4.7.11 (6)

PLC output

Control

signal

b0 DSTR

Positioning start: A move command is issued when this signal
turns ON.

4.7.11 (8)