IAI America PCON-CFA User Manual

Page 91

Advertising
background image

3. PCON-CA/CF

A


85

ᲣᲟᲖᱳ

PLC

PLC

Flat cable

Communication
cable


[4] Full direct mode: In this mode, the actuator is operated by specifying all values relating to position control

(target position, speed, acceleration/deceleration, etc.) directly as values.
Number of occupied bytes: 16CH

















[5] Remote I/O mode 2: In this mode, the actuator is operated by PIOs (24-V I/Os) via DeviceNet

communication.
The current-position and command-current read functions are available in addition to
the functions provided in mode [1].
Number of occupied bytes: 6CH










Target position: 100.00 mm
Positioning band: 0.10 mm
Speed specification:
100.0 mm/sec
Acceleration: 0.30 G
Deceleration: 0.30 G
Push current: 50%
Load current threshold: 0
Zone+: 50.00 mm
Zone-: 30.00 mm

PCON-CA/CFA supporting

DeviceNet

Actuator

PCON-CA/CFA not
supporting DeviceNet

PCON-CA/CFA supporting
DeviceNet

DeviceNet connection

PIO connection