3.11 Dome Communication

DOME ID

: Setting the dome camera address (ID) selection (1 ~ 3999)

PROTOCOL : AUTO, Fastrax II / IIE, Pelco-P / D

BAUD RATE : Setting the RS 485 Baud Rate (2400, 4800, 9600, 19200, 38400)

3.12 Alarm

Setup

NO : Alarm input number

PRI(Priority) : The lower number has higher priority. (0-8)

FUN(function) : Stored function number to be called by alarm.

IN

: X - ignore, ON - Enable

OUT : OUT1 ~ OUT2, OFF - No output.

HLD(HOLD) : Alarm will be held for programmed time (03 to 99 seconds)

LATCH : ON - Shows all alarms including past alarm.

OFF - Shows activated alarms only.

DWELL

:Means the dwell time during multiple alarms, 03 to 99 seconds.

The ALARM OUT setup is helpful when the outdoor housing is used with the dome.

Ex.) When you connect the relay output of the dome to the heater connector of the outdoor housing, the

relay output can operate during the setting time only.

DOME COMMUNICATION

DOME ID : 00XX

DOME ID : XX00

PROTOCOL : AUTO

BAUD RATE : 9600

PARITY : NONE

SAVE AND EXIT

ALARM SETUP

N P FUN IN O H L

01 1 001 X OFF 03 OFF

02 2 A01 X OFF 03 OFF

03 1 --- X OFF 03 OFF

04 1 --- X OFF 03 OFF

DWELL : 03

ALARM OUT SETUP

SAVE AND EXIT

ALARM OUT SETUP

OUT1 : ALARM

OUT2 : 1 MIN

EXIT