ALARM: The alarm output is operated during an alarm operation or by the short key of our keyboard.

1-5 MIN(minute): The alarm output is operated during this setting time only by the function run of

the dome menu or the short key of our keyboard.

NOTE: This 1-5 MIN setting is not operated by an alarm.

There are 9 levels of priority. The function can be selected by Preset, Auto scan, Pattern or Tour and “0” is

the highest priority. Lower priority alarms won’t be serviced until the higher priority alarm is completed.

Equal priority alarms will be serviced repeatedly with the dwell time.

3.13 Dome Setup

• HOME FUNCTION

SETUP

HOME FUNCTION

: None/ Tour/ Pattern / Auto Scan / Preset

FUNCTION NUMBER

: - - -

WAITING TIME

: 10~240 Seconds

FUNCTION ENABLE

: ON/ OFF

The Home function can be set so that the camera automatically goes to Preset, Tour, Pattern, Auto Scan after

the keyboard controller has been idle for a amount of time. For example, if the controller is idle for 120

seconds, the camera goes to preset 1.

Follow these steps to program the Home position:

1. Select Home Function by pushing the Joystick to the right or to the left to scroll through the None, Tour,

Pattern, Auto Scan or Preset functions.

2. Select Function Number and push the Joystick to the right or to the left. The recorded function number

will scroll.

3. Select WATING Time and push the Joystick to the right or to the left to select from 10 to 240 seconds.

4. Select Function Enable and turn to ON or OFF by pushing the Joystick to the right or to the left.

CONFIGURATION MENU

HOME FUNCTION SETUP

VIEW ANGLE SETUP

ORIGIN OFFSET

FACTORY DEFAULT

DOME RESET

OSD DISPLAY

SYSTEM SETUP

FUNCTION RUN

SYSTEM INFORMATION

EXIT

HOME FUNCTION SETUP

FUNCTION : NONE

NUMBER : ---

WATING TIME : 120 SEC

ENABLE : OFF

SAVE AND EXIT