Ac10 electronics – Warner Electric FM Series Foot Mounted Load Cells AC10 Measuring System A-B-C30 User Manual

Page 11

Advertising
background image

11

Warner Electric • 800-825-9050

P-2012-2

AC10 Electronics

The AC10 microprocessor-based electronics
adds ease of setup, versatility, and accuracy of
the overall system by eliminating the need for
potentiometers to adjust or setup the system.
All adjustments and system settings are per-
formed by using the pushbutton keys on the
board. During setup, alphanumeric prompts are
displayed on the 16-character LCD to guide the
user through the setup procedure.

Other features of the PSAC10 board include:

Two individually scaleable -10 to +10 volt DC
outputs
Run Mode LED

Programmable threshold relay
Cell#1/Total/Cell#2 switch connection
LCD Brightness Adjustment
Switch selectable 115/230 volt AC input
power

An RS422 Serial Output terminal is also provid-
ed for interfacing the AC10 system with a PC to
monitor and/or record the percent tension
applied to each Tensioncell. Data is transferred
in ASCII text format. The RS422 output can be
converted to RS-232.

J3

J4

J6

J5

Warner
Part# PSAC10
Serial#

Setup

Rapid

Exit

Setup

Enter

J7

J8

J9

J1

J2

Input Power
Selector Switch

Input Power
Terminal

Power On
Switch Terminal

Output #1
Output #2
Terminal

Cell #1/T otal/Cell#2
Switch Terminal

Tensioncell #1
Terminal

Tensioncell #2
Terminal

16-Character LCD

LCD Brightness
Adjustment

Pushbutton Keys

Threshold Relay
Terminal

RS-422 Output
Terminal

Run Mode LED

Spare

230V