J6 Analog Outputs Terminal

The J6 terminal provides the connections for the
two 10 volt DC outputs. Each output can provide
up to 30 milliamp current.

During setup, each output is individually
scaleable to meet the requirements needed to
calibrate the indicator, drive, or control connect-
ed to the board. The board circuitry is designed
to allow a switch to be connected at Terminal J5.
This switch allows the user to monitor the Output
#2 signal with respect to total tension, or the ten-
sion applied to either Tensioncell.

Terminal

Label

Description

J6-1

Out2

Scaleable -10 to +10 VDC Output

J6-2

Gnd

Common

J6-3

Out1

Scaleable -10 to +10 VDC Output

J64

Gnd

Common

J7 Threshold Relay Terminal

J7 provides the connections for utilizing the
AC10 Threshold Relay which is a form "C" dry
relay contact, rated at 1 Amp. During setup, the
threshold (percentage of total tension) is pro-
grammed to operate when the total tension is
either above or below the threshold value.

Initial Electrical Checks

Before applying power:

Note: Make sure that the Input Power Selector Switch matches the available input voltage.

Verify that the 8-position dip switch is set as follows:

Switch 1

2

3

4

5

6

7

8

Position

ON ON ON ON OFF ON ON ON

Apply power.

The red Run Mode LED in the lower right hand corner of the board should be flashing.

18

Warner Electric • 800-825-9050

P-2012-2

The contact may be wired to function in either
the normally open or normally closed state.

Terminal

Label

Description

J7-1

NC

Normally Closed Contact

J7-2

COM

Common

J7-3

NO

Normally Open Contact

J8 RS232 Output Terminal

J8 provides the cable connections for interfac-
ing the PSAC 10 board with a PC to monitor
total tension and tension applied to each
Tensioncell. Data is transferred in ASCII text for-
mat.

Terminal

Label

Description

J8-1

Gnd

Ground

J8-2

Tx-

Data Line +

J8-3

Tx+

Data Line-

J9 (Spare)

Out 2

Gnd

Out 1

Gnd

J6

Output #2 ( -10 to +10 VDC)

Common

Output #1 ( -10 to + VDC)

Common

1

2

3

4

Normally Closed

Common

Normally Open

J7

NC

COM

NO

1

2

3

Ground

Data Line -

Data Line +

J8

Gnd

Tx-

Tx+

1

2

3