Installation and Operation

A. Inspection Upon Delivery

Warner Electric tensioncells are carefully pack-
aged in sturdy reinforced cartons or wooden
boxes and are securely blocked or bolted in
place.

1. Upon receipt, examine the exterior of the con-

tainer for obvious damage or tampering.

2. Check the contents against the packing list.

3. Promptly report any damage or shortage to

both the carrier and Warner Electric.

B. Handling

Tensioncells can be handled manually.

C. Long Term Storage

While Warner Electric loadcells are plated, expo-
sure to weather, dirt, or moisture should be avoid-
ed when they are stored.

D. Mechanical Installation

Note: Refer to the Dimension Drawing Pages
10 and 11 of this manual for detailed
identification of all parts.

Tensioncells are designated as W1 and W2, one
being the mirror image of the other. (See Figure 7)

Warner Electric Wall Mounted Tensioncells are
mounted to the machine frame by a 5/8-11 UNC
bolt which is in line with the centerline of the
measuring roll shaft. This allows the Tensioncell to
be rotated around the centers of the measuring
roll and mounting bolt to achieve the proper
mounting angle. (Description of Operation on
Page 5)

The locating tab prevents the Tensioncell from
rotating and secures it in a permanent location.
It also provides a means of repeating rotary
position when the Tensioncell needs replace-
ment.

Note: Remove the 1/4" locking screw and
the 5/8" mounting bolt. This permits the roll
assembly with Tensioncells to be lifted out
of the machine.

Figure 7

1.63

1.06

.25 Dia.

5/8-11 UNC

1.06

W1

W2