Checking the firmware version, Rebooting the device – AMX Metreau Entry Communicator with Display MET-ECOM-D User Manual

Page 38

Advertising
background image

Using the Configuration Manager

32

Metreau Entry Communicators

Checking the Firmware Version

The firmware version is listed on the Summary of Device Settings page, in the Device Information
section at the top of the page.

Determining the IP settings of the Metreau Entry Communicator

1.

Browse to the Summary of Device Settings page.

2.

The IP settings are listed in the IP Settings section.

Rebooting the Device

1.

Open the Summary of Device Settings page.

2.

Click the Reboot button on the left bottom of the page.

Summary of Device Settings Page (Cont.)

IP Settings

IP

The IP setting of the unit; either Static or Dynamic.

Host

The hostname of the unit.

IP Address

The IP address of the unit.

Subnet Mask

The subnet mask associated with IP addressing

Gateway

The IP gateway used by this unit.

MAC Address

The MAC address of the unit.

NetLinx Settings

Status

The connection status of the device.

System Number

The NetLinx system number.

Device Number

The ICSP device number of this unit.

Master IP

The IP address of the NetLinx master connected to the device.

Master Port

Port number for the NetLinx master connected to the device.

Friendly Name

The friendly name of the device as it appears in the NetLinx master connection tree.

System Resources

File System

Amount of memory available to the file system.

RAM

Available RAM on the device.

It is necessary to reboot the device in order to apply changes to several
communication options, including Setting the IP and DNS Addresses, and setting the
ICSP connection and encryption status for the NetLinx Master (see page 35
).