Using the Configuration Manager

35

Metreau Entry Communicators

Configuration Page - NetLinx Settings Tab

Select the NetLinx Settings tab of the Configuration page to access the NetLinx Settings tab (FIG. 30).

Use the options in this tab to view and edit the ICSP connection to the NetLinx master.

Setting the ICSP Connection to the NetLinx Master

1.

In the Configuration page, select the NetLinx Settings tab.

2.

Enter the system number assigned to the ICSP system.

3.

Enter the device number to be assigned to the Metreau Entry Communicator in the Device Number
field.

4.

Enter the IP address of the master that the Metreau Entry Communicator is to connect with in the
Master IP/URL field.

FIG. 30

Configuration Page - NetLinx Settings tab

Configuration Page - NetLinx Settings Tab

Connection

Displays the ICSP connection status (Not Connected / Connected).

Mode

Master connection mode:
URL(TCP) - The device connects to the specific IP/URL of a master via a TCP

connection.

Auto - The device connects to the first master that responds. This setting requires you

set the System Number.

Listen - The device "listens" for the master to initiate contact. This setting requires you

provide the master with the device’s IP.

System Number

The ICSP system number.

Device Number

The ICSP device number.

Master IP/URL

IP or URL of master for URL master connection mode

Master Port Number The ICSP socket port number.

Username

The ICSP network username (required if the NetLinx master is encrypted).

Password

The ICSP network password (required if the NetLinx master is encrypted).

Friendly Name

The friendly name of the device as it appears in the NetLinx master connection tree.