Ending a doorbell call, Creating intercom pages – AMX Metreau Entry Communicator with Display MET-ECOM-D User Manual

Page 74

Advertising
background image

Using the NetLinx Module

68

Metreau Entry Communicators

The options in this page allow you see and view the incoming doorbell call, as well as adjust the
microphone and speaker volume levels for both the doorbell and the panel.

Door Microphone Level - Use the Up/Down arrow buttons to raise/lower the doorbell’s
microphone level. The current microphone level for the doorbell is indicated in the bargraph.
Press the Mute button to mute the doorbell microphone.

Door Speaker Level - Use the Up/Down arrow buttons to raise/lower the doorbell’s speaker
level. The current speaker level for the doorbell is indicated in the bargraph. Press the Mute
button to mute the doorbell speaker.

Panel Microphone Level - Use the Up/Down arrow buttons to raise/lower the panel’s
microphone level. The current microphone level for the panel is indicated in the bargraph.
Press the Mute button to mute the panel microphone.

Panel Speaker Level - Use the Up/Down arrow buttons to raise/lower the panel’s speaker
level. The current speaker level for the panel is indicated in the bargraph. Press the Mute
button to mute the panel speaker.

Ending a Doorbell Call

Press the End Call button in the Someone At The Door page to terminate the intercom session with the
doorbell.

Creating Intercom Pages

The easiest method of creating your own intercom pages is to start with the pages provided by AMX in
the module. You can change the aesthetics of the pages as long as the channel, address, level and links
remain untouched.

For the more ambitious panel designers, the necessary intercom directory buttons and their information
are contained in the Sample Intercom Page table on page 70.

Advanced Setup page

The Doorbell Mute buttons only perform mute. They do not perform un-mute.

Advanced Setup

Name

Description

Channel

Port:Code

Address

Port:Code

Allow Panel to be
Monitored

Toggle the panel’s ability to be monitored off and on.

1:11

Allow Panel to
Monitor

Toggle the panel’s ability to monitor off and on.

1:10

Room Name

The name of the panel as it appears in other intercom
directories. See Naming a panel section on page 66.

0:265

Name Panel

Set the name of the panel as it appears in other intercom
directories. (G4 Web Control: Server Name)

0:334

0:265

Back

Navigates the intercom panel to the intercom Setup page. This
requires a standard page flip to Setup.