6wiring – Proface FP3900 - 19 Flat Panel" User Manual

Page 13

Advertising
background image

13

• To avoid an electric shock, when connecting the FP’s power cord terminals to

the power terminal block, confirm that the FP’s power supply is completely
turned OFF, via a breaker, or similar unit.

• To avoid the dangers of fire, electric hazards and equipment damage, be sure

to use only the specified voltage when operating the FP.

• Since there is no power switch on the FP unit, be sure to attach a breaker-type

switch to its power cord.

„ Electrical Specification

„ Environmental Specification

6

Wiring

Item

Specification

Power Supp

ly

Type DC

Type AC

Rated Voltage

DC24V

AC100 ~ 240V

Allowable Voltage

DC19.2 ~ 28.8V

AC85 ~ 265V

Rated Frequency

-

50 / 60HZ

Allowable Frequency
Range

-

40 ~ 72Hz

Allowable Voltage Drop

10 ms (Max.)

1 cycle or less

(Voltage Drop Interval is

1s or more)

Power
Consumption

FP-3500T
Series

DC 24V 2.08A (or less)

(TYP 1.08A)

AC100V 0.90A or less

(TYP 0.55A)

AC240V 0.45A or less

(TYP 0.30A)

FP-3600T
Series

DC 24V 2.08A (or less)

(TYP 1.30A)

FP3650-
T41

-

In-Rush Current

30A (Max.)

60A (Max.)

Voltage Endurance

AC1000V 20mA

1 for minute

(between charging and

FG terminals)

AC1500V 20mA

for 1 minute

(between charging and

FG terminals)

Insulation Resistance

DC500V 10M

Ω (Min.)

(between charging and

FG terminals)

DC500V 10M

Ω (Min.)

(between charging and

FG terminals)

Item

Specification

Surrounding Air
Temperature

0 ~ 50ºC (The panel should not incline more than 30º)

Storage Temperature -20 ~ +60ºC
Ambient Humidity

10 ~ 90%RH

(No condensation, Wet bulb temperature: 39ºC max.)

Storage Humidity

Air Purity (Dust)

0.1mg/m

3

(Max.) (No electrically conductive dust is allowed)

Pollution Degree

For use in Pollution Degree 2 environment