Proface FP3900 - 19 Flat Panel" User Manual

Page 15

Advertising
background image

15

„ FP3500-T41-24V/FP3600-T41-24V (Type DC)
‹Power Cable specification

Use copper conductors only.

‹Power connector specification

Use the following wiring for FP. Those are Phoenix Contact products.

Cable thickness

0.75~2.5mm

2

(18-12 AWG)

Core wire condition

Single or Stranded wire

*1

*1.

In case of using a strand wire, inappropriate twisting of the core wire
may cause short circuit between each wire, or between wire and the
abutting electrode contact.

Core wire length

+

24V

-

0V

FG

A frame ground terminal connected with FP unit

• Ensure that the power cable is twisted where it is near the

connector.

• Kind of power cord is GMVSTBW2,5/3-STF-7,62, which are

Phoenix Contact products.

Recommended Drivers

SZF 1-0.6×3.5(1204517)

Recommended stick end
terminal

AI 0.75-8GY (3200519)

AI 1-8RD (3200030)

AI 1.5-8BK (3200043)

AI 2.5-8BU (3200522)

Crimp tool for recommended
stick end terminal

CRIMPFOX ZA 3 (1201882)

7mm[0.28inch]

FG

-

+

Power Cable Joint

Advertising