Determining the status of a management module

4

NOTE

Then the 40 GbE ports are in breakout mode on the 27x40 GbE and 12x40 GbE line cards, operating
status cannot be determined from LED operation.

Determining the status of a management module

You must have at least one management module (MM) active for the chassis to be functional. For
redundancy, you need two MMs. The active MM is designated by the blue Active LED on the front
panel.

Complete the following steps to determine the status of an MM.

1. Check the LED indicators on the module (

Figure 15

). The LED patterns may temporarily change

during POST and other diagnostic tests. For information about how to interpret the LED
patterns, refer to

Table 11

.

2. You can use the show mm command to see whether the management modules are enabled.

You can also use the show interface management 1/1 command to see the configuration
information.

Steady green

The port is online but has no
traffic.

No action required.

Flickering green

The port is online with traffic
flowing through the port.

No action required.

Medium flashing green
(on 1 seconds, then off
1 seconds)

Beaconing (used to identify
specific ports).

No action required.

Steady amber

The port is receiving light but it
is not online yet.

Reset the port by issuing a
shutdown and no shutdown
sequence on the port.

Slow flashing amber
(on 2 seconds, then off
2 seconds)

The port is disabled.

Enable the port by issuing a no
shutdown command.

TABLE 10

Line card LED descriptions (Continued)

LED purpose

Color

Status

Recommended action