Determining the status of a cid card, Table 16, Table 17 – Brocade VDX 8770-4 Hardware Reference Manual User Manual

Page 75

Advertising
background image

Brocade VDX 8770-4 Hardware Reference Manual

55

53-1002563-04

Determining the status of a CID card

4

For absent or faulty indications, contact the Brocade VDX 8770-4 supplier to order replacement
parts. You may also want to do this if the indication is below minimum or above maximum.

Table 16

describes the LED patterns for the fan.

Determining the status of a CID card

Each CID card has two serial EEPROMS (seeproms). One is the critical seeprom and the other is the
non-critical seeprom. Problems with the critical seeprom cannot be fixed with the CID Recovery
Tool. Only issues with the non-critical seeprom can be addressed.

Regular validation tests are run by the system comparing the CID cards to each other. If the
information is identical, then the chassis is operating correctly. Once a mismatch is detected, an
FFDC message is output to the RASlog. Refer to

Table 17

for possible messages.

unknown

Unknown fan unit installed.

faulty

Fan has exceeded hardware tolerance
and has stopped. In this case, the last
known fan speed is displayed. Could also
mean that the fan is improperly seated.

TABLE 16

Fan LED descriptions

LED purpose

Color

Status

Recommended action

OK

No light
(LED is off)

Fan does not have power.

Ensure that the fan is firmly
seated and has power.

Steady green

Fan has power.

No action required.

Fault

No light
(LED is off)

Fan is either healthy or
does not have power.

Ensure that the fan has power.

Steady amber

Fan has a failure (full or
partial).

Replace the fan.

TABLE 15

Output for show environment fan command (Continued)

Output

Explanation

TABLE 17

Messages that may indicate CID card problems

Error message

Issue

[EM-1020]...M1, ERROR ... A problem was found on

one or both CID cards (x), please run the CIDrecov

tool to get more information and recovery options.

Some kind of error or mismatch has
been detected in the CID card audit.

[EM-1021], ... M1, INFO, ... A CID card has been

inserted, a CID verification audit will be run to

detect any mismatches or other problems.

A second CID card is enabled and the
CID card audit will be run. If an error
is detected during the audit, an
EM-1020 message is generated.

[EM-1022], ... M1, WARNING, ... A CID card access

problem has been encountered, please run the

CIDrecov tool to get more information and recovery

options.

An error is detected during normal
access to the CID cards; typically, one
of the cards is corrupted or
inaccessible.

Advertising