Faulty management module indicators, Recording critical brocade vdx 8770-4 information, Removing a management module – Brocade VDX 8770-4 Hardware Reference Manual User Manual

Page 83

Advertising
background image

Brocade VDX 8770-4 Hardware Reference Manual

63

53-1002563-04

Management module removal and replacement

5

Faulty management module indicators

Confirm that you need to replace the management module. The following events might indicate
that a management module is faulty:

The status LED on the management module is lit steady amber, or the power LED is not lit.

The management module does not respond to Telnet commands, or the serial console is not
available.

The show mm command does not show that the management module is enabled.

Additional information from the show mm command indicates a problem.

The clock is inaccurate, or the management module does not boot up or shut down normally.

For more information about error messages, refer to the Network OS Message Reference.

Recording critical Brocade VDX 8770-4 information

Back up the chassis configuration before you replace a management module. Refer to

“Backing up

the configuration”

on page 37 for backup information.

Removing a management module

For this procedure, refer to

“ESD precautions”

and

Figure 21

.

The chassis continues to operate while a management module is being replaced if the redundant
management module is active and a failover has already occurred.

Complete the following steps to remove a management module.

1. Remove any cables connected to the module.

2. Unscrew the captive screws from both ejectors using the Phillips screwdriver.

3. Rotate both ejectors simultaneously toward the center of the module.

4. Pull the management module out of the chassis by the ejectors.

Advertising