Removal and replacement procedures, Introduction, Esd precautions – Brocade VDX 8770-4 Hardware Reference Manual User Manual

Page 77: Chapter 5, Chapter 5, “removal and replacement procedures

Advertising
background image

Brocade VDX 8770-4 Hardware Reference Manual

57

53-1002563-04

Chapter

5

Removal and Replacement Procedures

In this chapter

Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 57

ESD precautions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 57

Cable management finger assembly removal and replacement . . . . . . . . . 58

Line card removal and replacement . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 59

Management module removal and replacement . . . . . . . . . . . . . . . . . . . . . 62

Switch fabric module removal and replacement. . . . . . . . . . . . . . . . . . . . . . 65

Power supply removal and replacement . . . . . . . . . . . . . . . . . . . . . . . . . . . . 67

Fan removal and replacement . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 70

Air filter removal and replacement. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 71

Module filler panel removal and replacement . . . . . . . . . . . . . . . . . . . . . . . 74

Chassis ID card removal and replacement . . . . . . . . . . . . . . . . . . . . . . . . . . 75

SFP transceiver removal and replacement . . . . . . . . . . . . . . . . . . . . . . . . . . 76

QSFP transceiver removal and replacement . . . . . . . . . . . . . . . . . . . . . . . . . 78

Cable routing table . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 79

Introduction

NOTE

Refer to the safety notices before servicing (refer to

“Safety notices”

).

The field-replaceable units (FRUs) in the Brocade VDX 8770-4 can be removed and replaced
without special tools. The Brocade VDX 8770-4 can continue operating during many of the FRU
replacements if the conditions specified in the procedures are followed.

The following sections contain FRU removal and replacement procedures.

ESD precautions

The Brocade VDX 8770-4 contains ESD-sensitive FRUs. When working with any Brocade VDX
8770-4 FRU, use correct electrostatic discharge (ESD) procedures.

Wear a wrist grounding strap connected to chassis ground (if the Brocade VDX 8770-4 is
plugged in) or a bench ground. Refer to

“Port side of the Brocade VDX 8770-4”

on page 3 for

the location of the ESD jack.

Store ESD-sensitive components in anti-static packaging.