HATZ Diesel 4H50TIC User Manual

Page 40

Advertising
background image

Procedure

NOTICE

i

▪ After approx. 20 seconds the start procedure cuts off auto-

matically to protect the starter. If the engine is still not run-
ning after that, turn the starting key back to position "0" and
eliminate the cause (see the chapter 9.1 Fault table,
page 86
).

▪ Turn the starting key to position "0" every time you want to

start the engine.

▪ The anti repeat device in the ignition lock makes it impossi-

ble for the starter to engage while the engine is running and
become damaged.

Step

Activity

1

Remove the protective cap (4) from the ignition lock.

2

Insert the starting key all the way and turn to position "I".
Depending on the model, the following indicators light up:
▪ Charge control (10)
▪ Oil pressure display (9)
▪ Pre glow display (6)

NOTE: If the optional engine temperature display (8) lights up,
the coolant temperature is impermissibly high. Do not start the
engine; eliminate the cause.
When the optional pre glow display (6) goes out, continue with
step 3.

3

Turn the starting key to position "II".

4

As soon as the engine is running, release the starting key.
▪ The starting key springs back to position "I" and remains in

this position during operation.

▪ The charge control (10) and oil pressure display (9) go out.
▪ The operating display (11) lights up.

NOTICE

i

▪ In case of irregularities, switch off the engine immediately.
▪ Identify the fault and eliminate it.
▪ For details of troubleshooting, see the chapter 9.1 Fault ta-

ble, page 86.

4H50TIC

Operation and use

HATZ

Operator's Manual

41

Advertising