HATZ Diesel 4H50TIC User Manual

Page 92

Advertising
background image

Flash signal
Short – Long

Possible causes

Remedy

Chapter

1 – 3
Area affected:
Air supply

▪ Air filter is dirty.
▪ Charge air after

charge air cooler
too high.

▪ Charge air sen-

sor/intake low
pressure sensor
cabling faulty.

▪ Service the air fil-

ter

▪ Clean the radia-

tor fins.

▪ Check the ca-

bling.

8.2.14 Serv-
icing the air
filter (option-
al), page 80
8.2.6 Clean-
ing the radi-
ator fins,
page 64

1 – 4
Area affected:
Exhaust gas recir-
culation

▪ EGR sensor ca-

bling faulty.

▪ EGR radiator/

valve clogged by
deposits.

▪ Check the ca-

bling.

▪ Clean the EGR

radiator/valve.

2 – 1
Area affected:
Fuel low pressure
system

▪ Water in fuel.
▪ Fuel pressure

too low.

▪ Fuel temperature

too high.

▪ Fuel pump or

sensor cabling
faulty.

▪ Drain water from

the fuel prefilter.

▪ Check the fuel

tank level, refuel
if required.

▪ Replace both

fuel filters.

▪ Ensure the fuel is

sufficiently
cooled.

▪ Check the ca-

bling.

8.2.11
Draining the
water sepa-
rator,
page 73
7.7 Refuel-
ing, page 49
8.2.12
Changing
the fuel pre-
filter,
page 74
8.2.13
Changing
the fuel fine
filter,
page 77

2 - 2
Area affected:
Fuel high pressure
system

▪ Sensor system

(injectors, rail
pressure sensor,
pressure control
valve, high pres-
sure pump) ca-
bling faulty.

▪ Check the ca-

bling.

4H50TIC

Faults

HATZ

Operator's Manual

93