Type of fault

Possible causes

Remedy

Chapter

Stop signal from
monitoring ele-
ments that are as-
sociated with the
automatic switch-
off (optional):
▪ No oil pressure.
▪ Dirty air filter

unit.

▪ Fuel pressure

too low.

▪ Coolant level too

low.

▪ Excess coolant

temperature.

▪ Excess charge

air temperature.

▪ Faulty three

phase alternator.

▪ Check the oil lev-

el.

▪ Check the de-

gree of dirt con-
tamination of the
air filter, and
clean or renew it
if necessary.

▪ Check the fuel

flow, if necessary
change the fuel
prefilter and fine
filter.

▪ Top up coolant.
▪ Check radiator

fins and clean if
needed.

▪ Contact Hatz

service.

7.6 Check-
ing the oil
level and
adding oil if
necessary,
page 47
8.2.14 Serv-
icing the air
filter (option-
al), page 80
8.2.12
Changing
the fuel pre-
filter,
page 74
8.2.13
Changing
the fuel fine
filter,
page 77
8.2.4
Checking
the cooling
system,
page 57
8.2.6 Clean-
ing the radi-
ator fins,
page 64

Engine switches off
spontaneously dur-
ing operation.

The tank ran out of
fuel during opera-
tion

Fill with fuel.

7.7 Refuel-
ing, page 49

Fuel prefilter or fine
filter is clogged

Change the fuel fil-
ter.

8.2.12
Changing
the fuel pre-
filter,
page 74
8.2.13
Changing
the fuel fine
filter,
page 77