RANGER 9

B-3

OPERATION

B-3

WELDER CONTROLS-

Function and Operation

ENGINE “ON-OFF” SWITCH

When placed in the

ON

position, this switch

energizes the engine ignition circuit. When placed in
the

OFF

position, the ignition circuit is de-energized

to shut down the engine.

ENGINE “START” PUSH BUTTON SWITCH

Energizes engine starter motor.

“POLARITY” SWITCH

Three STICK/TIG (constant current) polarity settings:

DC+,DC- and AC

Two wire feed (constant voltage) settings:

DC+ and DC-

NOTE:

The setting of this switch must match the color

band setting of the Range Switch (both switches must
be set for the same welding process).

Never change the “POLARITY” switch setting
while welding. This will damage the switch.

“RANGE

SWITCH

Never change the “RANGE” Switch setting while
welding. This will damage the switch.

------------------------------------------------------------------------

CONTROL

SWITCH

Provides a fine welding current adjustment within the
Range Switch settings in the STICK/TIG mode and
welding voltage control with the Range switch set in
the wire feed mode.

“CONTROL AT WELDER /
REMOTE CONTROL” SWITCH

The toggle switch on he control panel labeled

CON-

TROL AT WELDER

and

REMOTE CONTROL

gives

the operator the option of controlling the output at the
welder control panel or at a remote station. Remote
connections are made at the 6-pin or 14-pin amphenol
connector.

For remote control, the toggle switch is set in the

REMOTE CONTROL

position.

For control at the welder control panel, the toggle
switch is set in the

CONTROL AT WELDER

position.

“WELDING TERMINALS” SWITCH

The Toggle switch labeled

WELDING TERMINALS

ALWAYS ON

and

WELDING TERMINALS

REMOTELY CONTROLLED

is used to control the

operation of the welder output contactor.
With the switch in the

ALWAYS ON

position, the out-

put contactor is closed at LOW and HIGH idle.

Low Idle - No Load
2200 RPM
High Idle - No Load
3700 RPM
AC CC Weld Output
250 Amps @ 25 Volts
DC CC Weld Output
250 Amps @ 25 Volts
DC CV Weld Output
250 Amps @ 25 Volts
Auxiliary Power
9,000 KVA

ONAN P220

.5Gallons/Hour

(1.9 Liters/Hour)

.9 Gallons/Hour

(3.4 Liters/Hour)

1.6 Gallons/Hour

(6.1 Liters/Hour)

1.9 Gallons/Hour

(7.2 Liters/Hour)

1.5 Gallons/Hour

(5.7 Liters/Hour)

1.7 Gallons/Hour

(6.4 Liters/Hour)

KOHLER

20 H.P. CH20S

.4 Gallons/Hour

(1.5 Liters/Hour)

1.0 Gallons/Hour

(3.8 Liters/Hour)

1.5 Gallons/Hour

(5.7 Liters/Hour)

1.7 Gallons/Hour

(6.4 Liters/Hour)

1.6 Gallons/Hour

(6.1Liters/Hour)

1.7 Gallons/Hour

(6.4 Liters/Hour)

Ranger 9 Approximate Fuel Consumption

ON

OFF

Explanation of Symbols that Appear on this Equipment

Low Idle

High Idle

CAUTION

STICK/TIG - (C0instant Current) 45,90,120,

Range Settings 6 160, 200, 250

WIRE FEED - (Constant Voltage)

Range Setting 3 LOW,MED,HIGH

Process Maximum Current

on Each Setting

CAUTION

Advertising