E-4

TROUBLESHOOTING

E-4

RANGER 9

Observe all Safety Guidelines detailed throughout this manual

If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact your
Local Lincoln Authorized Field Service Facility

for technical troubleshooting assistance before you proceed.

CAUTION

PROBLEMS

(SYMPTOMS)

POSSIBLE AREAS OF

MISADJUSTMENTS(S)

RECOMMENDED

COURSE OF ACTION

Battery does not stay charged

Output control on welder not
functioning.

Output control or remote not
functioning.

Wire feeder does not work when
connected to welder amphenol.

1.

Faulty battery.

2.

Faulty charging system.

3. Loose or broken lead in charging

circuit.

1.

Output control switch in wrong
position.

2.

Output control switch defective.

3. Output control potentiometer

defective.

4. Faulty wiring.

5. Faulty P.C. Board.

1.

Output control switch in wrong
position.

2.

Remote control leads broken in
control cable.

3.

Faulty wire feeder.

4.

Faulty P.C. Board.

1. Wire feeder circuit open or

faulty.

2. No 115V or 24V output from

stator.

3. Faulty wiring in control cable.

4.

Faulty wire feeder.

If all recommended possible areas of
misadjustment have been checked
and the problem persists, Contact
your local Lincoln Authorized
Field Service Facility.