Troubleshooting, Caution – Lincoln Electric IM753 RANGER 9 User Manual

Page 30

Advertising
background image

Engine will not go to high idle when
using auxiliary power.

Engine will not crank or is hard to
crank.

Engine will not start or shuts down.

Engine does not develop full power.

Engine is hard to start.

1.

No voltage signal from the
current sensor.

2.

Auxiliary power load less than
100 to 150 watts.

3.

Faulty P.C. Board.

1.

Battery will not hold a charge.
Faulty Battery.

2.

No or insufficient charging
current.

3.

Loose battery cable
connection(s).

4. Spark plugs fouled

1.

Out of fuel.

2. Low oil level.
3. Fault in fuel system.
4. Oil pressure switch faulty.
5. Generator terminal block

connection faulty

6. Faulty P.C. Board (Onan engine)

1.

Fuel filter clogged.

2.

Air filter clogged.

1.

Spark plugs do not have
specified gap.

2.

Spark plugs are fouled.

E-3

TROUBLESHOOTING

E-3

RANGER 9

Observe all Safety Guidelines detailed throughout this manual

If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact your
Local Lincoln Authorized Field Service Facility

for technical troubleshooting assistance before you proceed.

CAUTION

PROBLEMS

(SYMPTOMS)

POSSIBLE AREAS OF

MISADJUSTMENTS(S)

RECOMMENDED

COURSE OF ACTION

If all recommended possible areas of
misadjustment have been checked
and the problem persists, Contact
your local Lincoln Authorized
Field Service Facility.

Advertising