Liquid fertilizer application rates, 8 liquid fertilizer application rates – Seed Hawk Ground Drive: Granular & Liquid 2011 User Manual

Page 42

Advertising
background image

Seed Hawk

®

Manual

Granular and Liquid Tanks

Page 37

5.8 LIQUID FERTILIZER APPLICATION RATES


JOHN BLUE

PUMP


Perform the following steps to ensure that the liquid fertilizer pump is calibrated
properly:

1. Set the pointer, 1 Figure 39, on the

metering pump to a setting that
corresponds to the desired liquid
application rate.


2. Before seeding, accurately measure or

carefully estimate the amount of liquid in
the liquid fertilizer tank and note the
beginning area reading on the monitor
display.

3. Seed a significantly large area. Stop and

again measure or estimate the amount
of liquid remaining in the tank and note
the area covered.


4. Use the following formula to calculate the application rate:

Tank Level (initial) − Tank Level (�inal)

Area (�inal) − Area (initial)

= Application Rate gal ac

⁄ (L ha)


5. Adjust, if necessary, the pump setting and repeat the above procedure to confirm

application rate.