Maintenance, Maintenance schedule, Storage – Seed Hawk Ground Drive: Granular & Liquid 2011 User Manual

Page 46: 0 maintenance, 1 maintenance schedule, 2 storage

Advertising
background image

Seed Hawk

®

Manual

Granular and Liquid Tanks

Page 41

6.0 MAINTENANCE

6.1 MAINTENANCE SCHEDULE


Item

Procedure

Frequency

Notes

check

lube

clean

hours

Wheel Hubs
main frame

100

100 hr or annually
re-pack bearings or 2 pumps grease

Metering System
sprockets and chains

25

25 hr or every 2 days
use dry graphite lubricant

Metering Components

100

100 hr, or, before seeding, or,
between product changes

Fan System
intake

10

10 hr or daily
remove accumulated debris

Fan System
fan blades

10

10 hr or daily
must be intact and clean

Fill Auger or Conveyor
System

100

when changing between products, or,
when stored for long periods of time

Tanks and meters

100

When changing between products, or,
when stored for long periods of time

Fill Auger System
pillow block bearings

10/100

10 hr or daily, and,
100 hr or annually

Fill Auger System
universal joints

10/100

10 hr or daily, and,
100 hr or annually

Tank Return Line
open - drain in pail

100

at end of seeding season, or,
when stored for long periods of time

Tires
air pressure

10

10 hr or daily
inflate to proper pressure



NOTE: The bearings on each Stainless Steel meter are sealed.
DO NOT GREASE THESE BEARINGS.

6.2 Storage


Prior to storage remove all product from tanks and fill auger. As well, ensure that
the meters are emptied. If liquid tanks are equipped, purge all lines and add
antifreeze where necessary to avoid damage to liquid system caused by freezing.

NOTE: Failure to remove product prior to storage will greatly increase the
rate of corrosion in the tanks and meter.

Advertising